Atlanta Colocation Data Center 2
|
BUILDING: Enterprise Hosting Colocation Data Center 2
|
|
|
Address
Total Size
|
Atlanta, GA 30310 20,000 sq. ft. data center footprint 60,000 sq. ft. total enclosed space |
|
Data Center Construction |
Concrete & brick structure with reinforced steel. |
|
Shipping/Receiving |
Truck docks and small truck docks are able to support all of your shipping requirements. Secured Receiving area in Atlanta colocation data center is designated for customer-owned equipment. |
|
FLOOR SPACE |
|
|
Total Raised Floor |
20,000 sq. ft. of secure colocation space 15,000 additional sq. ft. of secure colocation space available |
|
COMMUNICATIONS |
|
|
Carriers |
Direct fiber access to Sprint, Level 3, Time Warner Telecom, BTN, Savvis, Cogent and Telia. Conduit access to Bell South, Nuvox, AT&T and other telecom companies. Connections to Comcast, DirectTV and Dish Network also available. |
|
Internal Cabling |
Copper or fiber access to carrier bandwidth using cable management trays throughout Atlanta colo data center. |
|
External Cabling |
Multiple secure entrances into secure colocation data center, including multiple CO redundancy and fiber access to primary carriers. |
|
POWER |
|
|
Power to Colo Facility |
On-site Georgia Power substation with 10MW of N+1 power fed by two diverse substations and one electrical grid. |
|
Generated Power |
(8) 500 kVA generators with redundant UPS systems to provide back-up power of over 4 Megawatts of usable power. |
|
Power Cabling |
All power cabling below data center floors are installed in conduit or flexible conduit with approved connectors to all equipment. |
|
All Systems |
Supported by 24/7/365 computer monitoring and secure colo data center engineers. |
|
COOLING |
|
|
Air Handling |
Supported by 24/7/365 computer monitoring and colo facility engineers. |
|
Air Quality |
Air temperature under floor delivered at 70° ± 5° with humidity at 50% ± 5%. |
|
FIRE PROTECTION |
|
|
Smoke & Heat Detection |
Smoke sensors above raised data center floors in Atlanta. |
|
Multi-Stage Protection |
Pre-action dry pipe system requires alert from two sensors, which activates pipe fill and a final stage when the temperature exceeds thresholds. |
|
PHYSICAL SECURITY |
|
|
Data Center Entrance |
All Atlanta colo entrances require card key access. Atlanta Data Center floor and secured areas require card key and two-factor biometric authentication (finger print and iris scan) |
|
Colocation Center Perimeter |
Security fence surrounds perimeter of property. Single site entrance with security gate. |
|
Security Guards |
Guards on site during non business hours. Active patrols both inside and outside the facility. |
|
Closed Circuit Video |
CCTV cameras cover inside and exterior of building, property perimeter, entrances, and Atlanta colocation data center floor. |
|
FACILITY MONITORING |
|
|
Facility Engineers |
Data Center engineers on site at Atlanta colocation center and available by pager. Engineers trained to control and maintain all critical facility components. |
|
Power Management |
Critical power system controlled by automated management system, which controls all switching. |
|
Environment Management |
Air temperature, humidity, fire detection, and water pressure all managed by automated control systems for the colocation center in Atlanta Georgia. |